Operating Instructions Safety Switch CES-AP-C01-CH
16
System status table
Operating mode
Actuator/door posi-
tion
Safety outputs OA
and OB
LED indicator,
output
State
STATE (green)
DIA (red)
Normal operation
closed on
Normal operation, door closed
closed on
flashes
quickly
2 Hz
Normal operation, door closed, actuator in limit range ¨ Re-adjust door
open off
1 x Normal operation, door open
Fault display
closed off
3 x Defective actuator (e.g. fault in code or code not readable)
X off
4 x Output error (e.g. short circuits, loss of switching ability)
X off
5 x Internal fault (e.g. component faulty, data error)
Key to symbols
LED not illuminated
LED illuminated
10 Hz (8 s)
LED flashes for 8 seconds at 10 Hz
3 x
LED flashes three times, and this is then repeated
X Any state
After the cause has been remedied, faults can generally be reset by opening
and closing the door. If the fault is still displayed afterward, briefly interrupt the
power supply. Please contact the manufacturer if the fault could not be reset after
restarting.
Important!
If you do not find the displayed device status in the System status table, this indi-
cates an internal device fault. In this case, you should contact the manufacturer.