Euchner CES-AP-CL2-CH (Multicode) Instrukcja Użytkownika Strona 20

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 26
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 19
Operating Instructions Safety Switch CES-AP-C.2-CH
20
Switching distances
Operating distance for center offset m = 0
(only in combination with actuator CES-A-BLN-...)
Parameter Value Unit
min. typ. max.
Switch-on distance - 15 -
mm
Assured switch-on distance s
ao 
1)
10 - -
Switching hysteresis 
1)
1 2 -
Assured switch-off distance s
ar
- in x/z direction
- in y direction
-
-
-
-
40
60
Typical operating distance
(only in combination with actuator CES-A-BLN-...)
Fig. 6: Typical operating distance
For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm 