Manual EKS Electronic-Key Adapter USB
Page 12/44 Subject to technical modifications 094485-04-11/13
4.2 Technical data, Electronic-Key adapter
All the electrical connections must either b
e isolated from the mains supply by a safety transformer
EN IEC 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent
Degree of protection acc. to EN 60529
IP 67 in mounted condition
Mounting cut-out according to DIN 43700
USB full speed (USB 1.1 and USB 2.0 compatible)
1 start bit, 8 data bits, 1 parity bit (even parity), 1 stop bit
green "Ready" (in operation)
yellow "Electronic-Key active" *
FSA Version (For Safety Applications) – parameters for floating semiconductor switching contacts LA and LB
Power supply U for load (LA, LB)
Switching current (with overload protection)
Output voltage U
A
(LA, LB) in switched state
Resistance in switched state
Utilization category according to AC-12
EN IEC 60947-5-2 AC-15
DC-12
50 mA / 24 V
Difference time between outputs** (LB first)
Connection screw terminals, 2 x 2-pole
Reliability values according to EN ISO 13849-1 (only FSA version)
Category (with connected safe evaluation)
d
Evaluation of data channel and one
switching contact LA
416 years
Evaluation of data channel and both
switching contacts LA and LB
803 years
* The LED illuminates yellow if there is a functional Electronic-Key in the Electronic-Key adapter.
** If access to the USB interface takes place during the insertion or removal of the Electronic-Key,
the difference time can be more than 200 ms.