AS-i 3.0 Command Interface Commands of the Command Interface
Subject to reasonable modifications due to technical advances Id.-No.: 102875 Issue date - 3.12.2007 EUCHNER GmbH + Co. KG
Kohlhammerstraße 16, D-70771 Leinfelden-Echterdingen Tel. +49/711/7597-0, Fax +49/711/753316
26
4.3.3.9 Command 8: Read „Safety Monitor unsorted by OSSD“
With this command the safety monitor is being read unsorted by OSSD
Following assignment is possible:
00
16
: Preprocessing
01
16
: OSSD 1
02
16
: OSSD 2
03
16
: OSSD 1+2
80
16
: Device doesn‘t exist
4.3.3.10 Command 9: „reserved“
This command is reserved for future developments.
Response buffer
Byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
000
16
1 monitor state
2 OSSD 1 state
3 OSSD 2 state
4
number of not green
1
devices, OSSD 1
1. The maximal value is 7, higher values are limited to 7.
5—
6 device index 32
7 device colour 32
8 device index 33
……
133 device colour 95
134 device index 32
135 assignment of the device 32 to the OSSD
……
261 assignment of the device 95 to the OSSD
See <chapter 6 "Appendix: Code description", on page 94> for a description of
the codes used for monitor state, OSSD state, device colours and assign-
ments to OSSDs and the "Safety-at-Work" monitor documentation.